CENTRAL Technical Data Book
Technical Data Book Update, February, 2002
Updating Instructions

Replace the Table of Contents dated 5-01 with the revised Table of Contents dated February, 2002.
Use the new Table of Contents as a guide when inserting the referenced new and revised technical data sheets.
REMOVE
INSERT
NOTES
1-8.0 (2-01)
1-8.1 (2-02)
Insert in place of the removed sheet.
The Series RFII Concealed Pendent Sprinklers are a redesignation for the Model BV4 and BV4-FR.
2-8.0 (2-01)
2-8.1 (2-02)
Insert in place of the removed sheet.
The Series RFII Concealed Pendent Sprinkler is a redesignation for the Model BV4-QREC.
2-13.0 (2-01)
2-13.0 (2-02)
Insert in place of the removed sheet.
The data sheet for the Model EC-25 Area/Density Extended Coverage Sprinklers has been reformatted. The inadvertent reference to U.S. Patent No. 5,829,532 has been removed.
3-1.1 (2-01)
3-1.5 (2-01)
3-2.1 (2-01)
3-1.2 (2-02)
3-1.6 (2-02)
3-2.2 (2-02)
Insert in place of the removed sheets.
The K25-1 Early Suppression Fast Reponse Sprinkler has been redesignated as the ESFR-25, and the K14 ESFR has been redesignated as the ESFR-1. The data sheet for the Model ESFR-17 Early Suppression Fast Response Sprinklers has been reformatted.
3-11.0 (2-01)
3-11.0 (10-01)
Insert in place of the removed sheet.
The data sheet for the Model ELO Multilevel Upright and Pendent has been revised to correct the Sprinkler Identification Numbers.
5-5.5 (3-01)
5-6.5 (3-01)
5-7.0 (2-02)
5-8.0 (2-02)
5-9.0 (2-02)
Insert in place of the removed sheets.
The Series DS-1 Dry Type Sprinklers are now being offered for sale in place of the S170 and S176 Dry Type Sprinklers. Also described in the new data sheets are Upright Dry Type Sprinklers, as well as Extended Coverage Horizontal Sidewall Dry Type Sprinklers.
5-11.0 (3-01)
5-13.0 (3-01)
5-14.0 (3-01)
5-11.1 (2-02)
5-14.1 (2-02)
Insert in place of the removed sheets.
The Series DS-2 Dry Type Sprinklers are now being offered for sale in place of the ELO series of Dry Type Sprinklers.
18-0.0 (4-01) 18-0.0 (2-02)
Insert in place of the removed sheet.
18-0.0 is a revised Fire Protection Submittal Sheet for Central Grooved Piping Products. 18-0.0 has been revised to include Listing and Approval Information for threaded fittings described on data sheet 21-3.0 offered through the line of Central
Grooved Piping Products.