Page 155 - Tyco-Grooved-Fire-Protection-Products-Installation-Handbook
P. 155

  APPROVED PRESSURE RATINGS 153
 Figure 730 Threaded Outlet 2 of 10
 Pipe2, 3 Sch.*
       Nominal Pipe Size
  Rated Pressure
 ANSI Inches DN
 O.D. Inches (mm)
   UL
   ULC
  FM
  VdS
   LPCB
  psi (bar)
   Sch. 10, 40
 4 x 1/2
100 x 15
  4.500 x 0.840 (114,3 x 21,3)
   300 (20,7)
  300 (20,7)
 300 (20,7)
   —
  —
 Sch. 10, 40
 4 x 3/4
100 x 20
 4.500 x 1.050 (114,3 x 26,7)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 4 x1
100 x 2
 4.500 x 1.315 (114,3 x 33,4)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 4 x 1-1/4
100 x 32
 4.500 x 1.660 (114,3 x 42,4)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 4 x 1-1/2
100 x 40
 4.500 x 1.900 (114,3 x 48,3)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 4 x2
100 x 50
 4.500 x 2.375 (114,3 x 60,3)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 4 x 2-1/2
100 x 65
 4.500 x 2.875 (114,3 x 73,0)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 4 x 76,1
100 x 65
 4.500 x 3.000 (114,3 x 76,1)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 4 x3
100 x 80
 4.500 x 3.500 (114,3 x 88,9)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 5 x 1-1/2
125 x 40
 5.563 x 1.900 (114,3 x 48,3)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 5 x2
125 x 50
 5.563 x 2.375 (114,3 x 60,3)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 5 x 2-1/2
125 x 65
 5.563 x 2.875 (114,3 x 73,0)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 5 x3
125 x 80
 5.563 x 3.500 (114,3 x 88,9)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 6 x 1-1/4
150 x 40
 6.625 x 1.660 (168,3 x 42,4)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 6 x 1-1/2
150 x 40
 6.625 x 1.900 (168,3 x 48,3)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
 6 x2
150 x 50
 6.625 x 2.375 (168,3 x 60,3)
 300 (20,7)
  300 (20,7)
 300 (20,7)
 —
  —
 Sch. 10, 40
  6 x 2-1/2
150 x 65
  6.625 x 2.875 (168,3 x 73,0)
  300 (20,7)
   300 (20,7)
  300 (20,7)
  —
   —
 1. For 8 inch sizes, minimum allowed pipe wall thickness is 0.188.
2. See Agency website for Listing/Approvals of other pipe specifications:
UL Website - see Online Certificate Directory, www.ul.com
FM Global Website - www.approvalguide.com
3. See Agency website for Listing/Approvals of other pipe specifications:
LPCB Website - see Search Our Listing - Automatic Sprinklers, Water Spray and Deluge Systems, www.redbooklive.com
VdS Website - see certifications, www.vds.de
* See Pipe Schedule Key on pages 127-128.